We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Wall mount container for batteries and DC-UPS; 12-24-48 VDC, 1,2-20 Ah SFP544
SKU
SFP544
• Input: Single-phase 115-230-277 Vac
• Output: 12-24-48 Vdc
• Battery temperature compensation
• Deep Discharge protections
• Charging curve IUoUO, constant voltage and constant current
• Battery Life Test function (Battery Care)
• Four charging levels: Absorption, Boost, Float and Recovery
• Protected against short circuit and inverted polarity
• Signal Output (contact free) for discharged or damaged battery, Modbus, Mains/Back-Up
• Combined with DC UPS series
• Connectivity: ModBus RTU; Ethernet
• Wall Mount
• Protection degree IP30
SFP544 is a container designed to be used as a panel of full power, can be integrated inside by the whole range of ADEL System DC UPS 12-24-48 Vdc, even with batteries up to 20Ah or one up to 45Ah for 12V system or for 24V system with additional battery cabinet SFP-BB45. Specific for application in Fire Protection systems.
Power supply unit conform to European standard EN54.4. the device provide power for the main panel, in field device and stand by Battery. The maximum total current depending on the type of CBI’s chosen at least 20 A that can be distributed between load and battery. The CBI device can supply the load and in the main time recharge and detect the batteries.
When main fail, automatically the CBI’S switch the battery to the load without any output interruption. In any situation the battery it is tested charged and temperature charging compensated, by external temperature sensor. By DPY351 or DPY353 it is possible monitoring all kind of state and alarm that can be transmitted by Dry contact or by Ethernet. The alarm Type are: Battery Fault, Main o Back Up, Generic Fault. By ADELView system, it is possible monitoring and configuring the device in other area.
Power supply unit conform to European standard EN54.4. the device provide power for the main panel, in field device and stand by Battery. The maximum total current depending on the type of CBI’s chosen at least 20 A that can be distributed between load and battery. The CBI device can supply the load and in the main time recharge and detect the batteries.
When main fail, automatically the CBI’S switch the battery to the load without any output interruption. In any situation the battery it is tested charged and temperature charging compensated, by external temperature sensor. By DPY351 or DPY353 it is possible monitoring all kind of state and alarm that can be transmitted by Dry contact or by Ethernet. The alarm Type are: Battery Fault, Main o Back Up, Generic Fault. By ADELView system, it is possible monitoring and configuring the device in other area.
| SKU | SFP544 |
|---|---|
| Output Current | By selected CBI unit |
| Input Voltage | 90 - 305 VAC |
| Battery | Without batteries |
| Compability | CB and CBI series |
| Construction | Wall mountable |
| Dimensions | 305 x 360 x 185 mm |
| Weight | 6,8 kg |
| Brand | Adel |
| Package | 1 |
| Availability | 1 - 3 days |
Write Your Own Review