250 W AC/DC DIN Rail DC UPS; 12 or 24 VDC CBI2501224A

SKU
CBI2501224A

• Universal Input Range: 90…305 VAC & 140...340 VDC
• Package: Can be installed on DIN rail TS-35
• Output Selectable: 12 Vdc 10A or 24 Vdc 10A
• Suited for the following battery types: Lead Acid, AGM, GEL, NiCd, NiMh, Li-Ion and LiFePO4
• Automatic diagnostic of battery status. Charging curve IUoUO, constant voltage and constant current
• Battery Life Test function
• 5 charging levels: Recovery, Boost, Absorption, Float (Forced trickle / Forced float / Auto float-trickle), and Refresh
• High Efficiency >92%
• Operating Temperature: -25…+70 °C (with derating)
• Isolation class I
• Isolation output-input: 4000 VAC
• Protected against short circuit and inverted polarity
• Contact free signal outputs: for discharged or damaged battery and for mains or Back-UP
• Modbus RTU for Monitoring, Configuration, History and Alarms
• ADELBus: integrated monitoring and control of ADELSystem devices
• MTBF: >300 000 h (IEC 61709)
• Standardit: IEC/EN 62368-1, CE
• EMC: 2014/30/UE, 2014/35/UE, IEC 61000-6-2,-3,-4
• Dimensions: 50x135x135mm
The CBI2501224A is the new dual voltage DC-UPS solution with integrated Modbus RTU RS485 and CANBUS J1939 interface. This is a revolutionary line, designed to provide uninterruptible power whatever condition the system is in, by means of sophisticated and completely automatic management of any type of industrial battery thanks to charger's different charging profile for Lead Acid, AGM, GEL, NiCd, NiMh, Li-Ion and LiFePO4 battery technologies.

The new DC-UPS unit has wide input voltage range: 100 – 240 – 277VAC and 140 - 340VDC.

Direct plug connectors with “push in” technology reduce connection times, increasing installation efficiency without compromising safety.

The CBI2501224A use switching technology with microcontrollers and optimize the loading and unloading times of the accumulator without a deep discharge, the switching from the battery to the charger without any interruption, automatic protection without fuse against the reserve polarity, short circuit and overload and overvoltage.

The Modbus RTU RS485 protocol is integrated into the device, offering the possibility to remotely monitor power parameters and battery health. Configuration of the device is also possible via push button, avoiding the use of jumpers.

The unit is equipped with two load outputs, providing the opportunity of connecting two different loads directly to the DC-UPS.

Available options:
CBI-Holders Battery modules for sealed lead acid batteries
Multifunctional display for managing ADELSystem devices connected in an ADELBus network
Temperature Probe.
More Information
SKUCBI2501224A
Output Power250 W
Output voltage10,0 - 14,4 VDC
22,0 - 28,8 VDC
Output Current10,0 A
Input Voltage90 - 305 VAC
Input Voltage DC140 - 340 VDC
Efficiency> 92%
TechnologySwitcher, regulated
Isolation Voltage4 kVAC
MTBF>300 000 h
Operating Temperature-25…+70 °C
ConstructionDIN rail
Input ConnectionsPush-in
Output ConnectionsSnap-on terminals
Dimensions50 x 135 x 135 mm
Weight950 g
BrandAdel
Package1
Availability2 - 3 weeks